Male Barb Adapter Manufacturer,Supplier and Exporter in India
Product Code : SCL-GA-10341
The 24/40 Male Barb Adapter is a laboratory glassware connector used for linking compatible 24/40 female ground-glass joints to flexible tubing through a 3/8 barb connection. It is suitable for chemistry labs, research labs, universities, pharmaceutical labs, testing labs, exporters, and institutional procurement teams.
Product Description
The 24/40 Male to 3/8 Barb from Lab Glassware Manufacturer is intended for glassware assemblies where a male 24/40 joint must connect to tubing for gas transfer, vacuum connection, vapour routing, or fluid-handling support. The confirmed product data identifies a 24/40 male joint and 3/8 barb connection.
This adapter is useful in modular laboratory systems that require a transition between rigid ground-glass apparatus and flexible tubing. Exact glass type, barb outside diameter basis, hose material compatibility, total length, vacuum suitability, pressure suitability, and certification status should be confirmed before final catalogue or procurement use.
Key Features
- 24/40 male joint: designed for compatible 24/40 female ground-glass laboratory connections.
- 3/8 barb connection: supports compatible flexible tubing where hose fit is verified.
- Glass-to-tubing transition: helps connect jointed glassware to gas, vapour, vacuum, or transfer lines.
- Capacity not applicable: this is a connection adapter, not a measuring vessel.
- Inline assembly support: suitable for compact laboratory setups requiring a direct tubing interface.
- Laboratory utility: useful in distillation, vacuum-line, gas-transfer, and receiver assemblies.
- Specification-dependent use: pressure, vacuum, chemical, and hose compatibility must be verified.
Technical Specifications
|
Specification |
Detail |
|
Product Name |
24/40 Male to 3/8 Barb |
|
Primary Keyword |
24/40 Male Barb Adapter |
|
Secondary / Semantic Keywords |
24/40 glass barb adapter, male ground glass adapter, 3/8 hose barb adapter, laboratory tubing adapter, glassware hose connector, vacuum tubing adapter, gas transfer adapter, laboratory glass connector |
|
Brand / Supplier |
Lab Glassware Manufacturer |
|
Product Category |
Laboratory Glassware / Glassware Adapter / Hose Barb Adapter |
|
Capacity |
Not applicable |
|
Ground Joint |
24/40 male |
|
Barb Connection |
3/8 barb |
|
Intended Users |
Universities, chemistry labs, organic chemistry labs, research labs, pharmaceutical labs, testing labs, exporters, distributors, and procurement teams |
What's Included in the Kit
- 24/40 Male to 3/8 Barb Adapter
- Tubing, hose clamp, joint clip, certificate, storage case, or accessories
Applications / Uses
- Connecting compatible 24/40 female ground-glass joints to flexible tubing
- Supporting gas-transfer, vapour-transfer, and vacuum-line assemblies
- Linking laboratory glassware to hose-based connections where compatible
- Use in distillation, receiver, filtration-support, and solvent-handling setups
- Teaching ground-glass joint and tubing connection principles in chemistry labs
- Research, pharmaceutical, testing, and preparation-room glassware workflows
How to Use the 24/40 Male to 3/8 Barb
- Confirm that the receiving glassware has a compatible 24/40 female joint.
- Confirm that the tubing fits the 3/8 barb without splitting, slipping, or leaking.
- Inspect the adapter for cracks, chips, scratched joints, blocked passages, or residue.
- Clean and dry the ground joint and barb before assembly.
- Insert the 24/40 male joint gently into the matching female socket.
- Push compatible tubing onto the barb and secure it with a clamp if required by the method.
- Support the full assembly before applying gas flow, vacuum, liquid transfer, or vapour movement.
- After use, vent safely, disconnect tubing, clean, dry, and store the adapter.
Safety note: Do not use this adapter under vacuum, pressure, heat, hazardous vapours, or corrosive chemical conditions unless the glass type, barb fit, tubing material, joint seal, and complete apparatus rating are verified. Use eye protection, gloves, clamps, and a fume hood where required.
Care & Maintenance
- Clean the bore, joint, and barb immediately after use to prevent residue buildup.
- Rinse and dry before storage to reduce contamination and joint sticking.
- Store in padded glassware storage to protect the 24/40 male joint and barb end.
- Remove from service if cracks, chips, leaks, scratched joints, or stress marks appear.
Why Choose Lab Glassware Manufacturer
Lab Glassware Manufacturer manufactures and exports laboratory glassware, scientific laboratory instruments, lab experiment setups, science kits, didactic models, and STEM learning products. The brand serves schools, colleges, universities, laboratories, exporters, and institutional procurement buyers. Its product catalogue supports chemistry, biology, physics, laboratory glassware supply, and education-focused scientific experimentation.
Frequently Asked Questions
What is a 24/40 Male Barb Adapter used for?
A 24/40 Male Barb Adapter is used to connect compatible 24/40 female ground-glass joints to flexible tubing through a 3/8 barb connection.
What does 24/40 mean on this adapter?
24/40 is the confirmed ground-glass joint reference. It should be used only with compatible 24/40 laboratory glassware joints.
What does 3/8 barb mean?
3/8 barb refers to the tubing connection size stated in the product name. Confirm whether this is outside diameter, nominal tubing size, or another sizing basis before procurement.
Is this adapter made from borosilicate glass?
The exact glass type is not confirmed for this specific item. Add borosilicate, quartz, or other material claims only after verification.
Can this adapter be used with vacuum tubing?
It can support tubing connection where compatible, but vacuum suitability is not confirmed. Verify the adapter, hose, clamp, joint fit, and complete apparatus rating before vacuum use.
Does the adapter include tubing or clamps?
Tubing, clamps, joint clips, certificates, and accessories are not confirmed. List them only after checking the supplied configuration.
For related adapter and jointed glassware products, explore glassware adapters, laboratory glass joints, adapters multiple 3 neck, and laboratory glassware.