Stainless Steel Cold Trap Setup - R-2-TRAP-2 Single Unit Manufacturer,Supplier and Exporter in India
Product Code : SCL-GLE-10358
The Stainless Steel Cold Trap Setup is a laboratory vacuum-line accessory used for trapping condensable vapours before they reach a pump, receiver, or downstream apparatus. The R-2-TRAP-2 single setup is intended for compatible distillation, solvent recovery, evaporation, and vacuum protection workflows.
Product Description
The R-2-TRAP-2 Single Stainless Steel Cold Trap Set-up from Lab Glassware Manufacturer is specified as a single cold-trap setup with stainless-steel construction. It is used where vapours or solvent mist must be condensed or captured before entering sensitive vacuum equipment.
A cold trap is commonly placed between a vacuum source and the working apparatus. The exact stainless-steel grade, trap volume, port size, coolant compatibility, vacuum rating, gasket type, and included hardware must be confirmed before final catalogue publication or procurement approval.
Key Features
- Single cold-trap setup: intended for one vacuum-line protection position.
- Stainless-steel construction: specified in the product name; exact grade must be confirmed.
- Vacuum-line support: helps reduce vapour carryover into compatible pumps or receiving lines.
- Capacity not applicable: this is a trap setup, not a calibrated measuring vessel.
- Solvent recovery workflow use: suitable for compatible evaporation, distillation, and recovery assemblies.
- Laboratory durability focus: stainless-steel trap bodies are selected where robust handling is required.
- Specification-dependent safety: pressure, vacuum, coolant, and chemical compatibility must be verified.
Technical Specifications
|
Specification |
Detail |
|
Product Name |
R-2-TRAP-2 Single Stainless Steel Cold Trap Set-up |
|
Primary Keyword |
Stainless Steel Cold Trap Setup |
|
Secondary / Semantic Keywords |
single cold trap setup, stainless steel laboratory cold trap, vacuum cold trap, solvent vapour trap, pump protection trap, distillation cold trap, rotary evaporator cold trap, laboratory vacuum accessory |
|
Brand / Supplier |
Lab Glassware Manufacturer |
|
Product Category |
General Lab Equipment / Vacuum Accessory / Cold Trap Setup |
|
Model / Reference |
R-2-TRAP-2 |
|
Configuration |
Single cold trap setup |
|
Capacity |
Not applicable |
|
Material |
Stainless steel |
What's Included in the Kit
- R-2-TRAP-2 Single Stainless Steel Cold Trap Set-up
- Hose, clamp, gasket, lid, connector, stand, certificate, or packaging
Applications / Uses
- Protecting compatible vacuum pumps from condensable vapours
- Solvent recovery and vapour trapping in laboratory workflows
- Use with compatible distillation, evaporation, and vacuum assemblies
- Reducing vapour carryover in preparation rooms and research labs
- Pharmaceutical, QC, chemistry, and testing-lab vacuum-line support
- Advanced teaching demonstrations on cold trapping and vacuum protection
How to Use the R-2-TRAP-2 Single Stainless Steel Cold Trap Set-up
- Confirm that the trap connection size matches the vacuum line and apparatus.
- Inspect the trap, seals, ports, clamps, and fittings before assembly.
- Place the trap between the working apparatus and the vacuum source.
- Add only the verified coolant type and volume recommended for the setup.
- Connect hoses or fittings securely without twisting or stressing the line.
- Start cooling before applying vacuum when required by the method.
- Monitor the trap during operation and avoid overfilling or blockage.
- Vent safely, allow controlled warm-up, empty condensate, clean, and dry after use.
Safety note: Do not use this cold trap with incompatible solvents, pressure generation, cryogenic coolant, corrosive vapours, or high-vacuum conditions unless the stainless-steel grade, seals, ports, coolant method, and complete apparatus rating are verified.
Care & Maintenance
- Empty and clean the trap after each use to prevent residue buildup.
- Dry all ports, seals, and internal surfaces before storage.
- Inspect seals, fittings, and stainless-steel surfaces for wear or corrosion.
- Remove from service if leaks, dents, damaged ports, or seal failure appear.
Why Choose Lab Glassware Manufacturer
Lab Glassware Manufacturer manufactures and exports laboratory glassware, scientific laboratory instruments, lab experiment setups, science kits, mathematics kits, didactic models, and STEM models. Its catalogue supports vacuum-related adapters, condensers, stopcocks, flasks, and general lab equipment for education, research, testing, and institutional procurement.
Frequently Asked Questions
What is a Stainless Steel Cold Trap Setup used for?
A Stainless Steel Cold Trap Setup is used to capture condensable vapours before they reach a compatible vacuum pump or downstream laboratory apparatus.
What does R-2-TRAP-2 mean?
R-2-TRAP-2 is the model or reference name supplied for this single stainless steel cold trap setup. Confirm internal SKU details before publication.
Is the trap volume confirmed?
No. The supplied product name does not confirm trap volume. Add the volume only after checking the technical datasheet.
Can it be used with dry ice or liquid nitrogen?
Coolant compatibility is not confirmed. Use dry ice, liquid nitrogen, or other coolants only after verifying the trap design and safety procedure.
Can this cold trap be used under vacuum?
It is intended for compatible vacuum-line workflows, but the exact vacuum rating is not confirmed. Verify the complete apparatus rating before use.
Does the setup include hoses or clamps?
Hoses, clamps, connectors, seals, stands, and accessories are not confirmed. List them only after checking the supplied configuration.
For related vacuum and laboratory setup products, explore glassware adapters, laboratory glass condenser, laboratory glass stopcocks, and general lab equipment.
