U-core with yoke flipped Manufacturer,Supplier and Exporter in India

U-core with yoke flipped

Product Code : SCL-EI-10546

The U-core with yoke flipped is a physics laboratory magnetic-core accessory used for demonstrating magnetic circuits, electromagnetism, induction, transformer action, and flux-path behaviour. It is suitable for schools, colleges, STEM laboratories, electronics trainers, physics practical rooms, and student experiments involving coils, AC supply, DC supply, magnetic fields, and laminated iron cores.

Product Description

The U-Core with Yoke Flipped from Lab Glassware Manufacturer is intended for practical demonstrations where a U-shaped magnetic core and a detachable yoke are used to complete or modify a magnetic circuit. The yoke may be positioned or flipped according to the experiment design, helping students observe how core alignment, air gap, flux path, and coil arrangement affect magnetic behaviour.

This product should be described as a magnetic-core accessory, not as a complete transformer or electromagnet apparatus unless coils, clamps, pole pieces, power supply, connecting leads, and experiment guide are confirmed in the final supply. Final core material, lamination type, cross-section, yoke dimensions, fixing screw, clamping system, coil compatibility, and safe electrical ratings must be verified before catalogue publication or tender submission.

Key Features

  • U-shaped magnetic core with detachable or repositionable yoke for classroom experiments.
  • Useful for teaching magnetic circuits, flux path, air gap, induction, and transformer principles.
  • Supports experiments with compatible coils, power supplies, pole pieces, and clamping devices.
  • Suitable for school physics labs, electronics labs, STEM labs, and engineering training rooms.
  • Helps students observe how closing or changing a magnetic path affects magnetic performance.
  • Can be used in demountable transformer, electromagnet, and induction demonstrations where compatible accessories are supplied.
  • Core size, lamination, yoke orientation, fixing method, and coil compatibility must be confirmed.

Technical Specifications

Specification

Detail

Product Name

U-Core with Yoke Flipped

Brand

Lab Glassware Manufacturer

Product Category

Physics Lab Equipment / Electromagnetism Apparatus / Magnetic Core and Yoke Accessory

Intended Users

School physics labs, college laboratories, STEM classrooms, electronics labs, engineering trainers, science teachers, lab technicians, and institutional buyers

Primary Keyword

U-core with yoke flipped

Secondary Keywords

U-core with yoke, magnetic U-core, demountable transformer core, laminated iron core, transformer yoke, electromagnetism apparatus, magnetic circuit core, school transformer experiment

Core Type

U-shaped magnetic core with detachable/repositionable yoke [confirm]

Yoke Orientation

Flipped / reversible / repositionable yoke [confirm exact design]

Standards / Certifications

No certification claimed; add only if verified by datasheet, inspection report, or electrical safety document

What's Included in the Kit

  • U-shaped magnetic core 
  • Detachable or flipped yoke 
  • Fixing screw, clamp, spring clip, or holding accessory
  • Compatible coils, pole pieces, or coil holders 
  • Connecting leads, power supply, or transformer accessories 
  • Instruction sheet, experiment guide, or compatibility note 

Applications / Uses

  • Demonstrating magnetic flux paths in a U-core and yoke arrangement.
  • Teaching electromagnetism, induction, transformer action, and magnetic circuit closure.
  • Showing the effect of air gaps, yoke position, core alignment, and coil placement.
  • Using with compatible coils for demountable transformer and electromagnet demonstrations.
  • Supporting experiments in magnetic field strength, flux linkage, and induced voltage where suitable accessories are supplied.
  • Using with related products from Physics Lab Equipment.
  • Supporting electronics and magnetism practical rooms through General Lab Equipment.
  • Requesting institutional or OEM supply through Tenders/OEM and Contact Us.

How to Use the U-Core with Yoke Flipped

  1. Place the U-core on a stable, dry, insulated laboratory bench or compatible base.
  2. Confirm that the coils, clamp, yoke, and power supply match the core specification.
  3. Fit the coil or coils onto the U-core limbs according to the experiment diagram.
  4. Place or flip the yoke into the required orientation to complete or modify the magnetic circuit.
  5. Secure the yoke using the confirmed fixing screw, clamp, or spring clip.
  6. Connect the coils to a suitable low-voltage AC or DC supply as specified by the experiment.
  7. Observe magnetic attraction, induced voltage, flux-path change, transformer action, or electromagnet behaviour.
  8. Switch off power and allow the core and coils to cool before changing coil connections or yoke position.

Safety note: Use only within the confirmed coil voltage and current ratings. Do not touch energized terminals, overload coils, short-circuit the power supply, or handle hot cores and coils immediately after use.

Care & Maintenance

  • Keep the core, yoke, clamp, and contact faces clean, dry, and free from rust or dust.
  • Store the yoke with the U-core to avoid mismatch or damage to mating surfaces.
  • Do not drop the laminated core or bend the yoke, as this can affect alignment.
  • Inspect coils, leads, insulation, and fixing screws before each practical session.
  • Use light protective oil only if recommended by the confirmed product guide.

Why Choose Lab Glassware Manufacturer

Lab Glassware Manufacturer supplies laboratory glassware, scientific laboratory instruments, lab experiment setups, science kits, mathematics kits, didactic models, and STEM models for educational and institutional buyers. The brand supports schools, colleges, universities, research laboratories, distributors, and export customers with physics, electronics, engineering, and general laboratory products. This U-core with yoke flipped can be supplied as an electromagnetism and transformer accessory when final mechanical and electrical compatibility details are verified. Buyers should confirm core size, material, yoke arrangement, coil compatibility, clamping method, and documentation before procurement.

Frequently Asked Questions

What is a U-core with yoke flipped used for?

A U-core with yoke flipped is used to demonstrate magnetic circuits, flux paths, electromagnetism, transformer action, induction, and the effect of changing or closing a magnetic path.

Is this a complete transformer kit?

No. It should be treated as a U-core and yoke accessory unless the final quotation confirms that coils, clamps, power supply, leads, and experiment guide are included.

What does “yoke flipped” mean?

It usually means the yoke is repositioned or reversed in the setup to change the magnetic-core arrangement. The exact flipped orientation must be confirmed from the final product drawing or manual.

Can it be used with coils?

Yes, if compatible coils are supplied or specified. Confirm coil bore size, turns, voltage rating, current rating, and mounting clearance before use.

Is the core laminated?

Lamination is not confirmed for this supplied product. Add laminated iron, soft iron, ferrite, or silicon-steel details only after verifying the product specification.

What should be confirmed before ordering?

Confirm core material, lamination, cross-section, height, width, yoke dimensions, flipped orientation, clamping method, compatible coils, included accessories, packing, and instruction guide availability.

For more electromagnetism, transformer, induction, and student electronics apparatus, explore Physics Lab Equipment from Lab Glassware Manufacturer.

   
Supply of U-core with yoke flipped from to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe

Office Address

Works:Laboratory Glassware Manufacturer Pvt. Ltd. Factory No. 449 , Industrial Area Ambala Cantt, Haryana, India

[email protected]

Follow Us